Contents
Wrapped water well tubular products stacked on supports in the OFD workshop
Wrapped water well tubular products stacked on supports in the workshop.

Start with one approved inspection basis

Before a wire-wrapped well screen leaves the factory, the review should connect three things: the specified product, the physical screen and the records supplied with it. A clean surface or a single nominal slot value cannot answer all three questions.

Use the approved drawing revision, material specification and inspection plan as the acceptance basis. Identify the screen type, quantity, nominal slot, permitted variation, overall and active screen lengths, end connections and any agreed tests. Record which requirement each check addresses. Do not substitute a generic internet tolerance for the project specification.

This checklist is a review framework for buyers and inspectors. It does not establish a universal inspection frequency or replace the well designer’s mechanical and hydraulic assessment.

Measure slot openings at recorded locations

The nominal slot describes the intended opening; inspection records should describe what was measured. Use a suitable, verified measuring method for the specified opening and record the locations and results. Measurements near the ends and across different parts of the active length help reveal local variation that one reading can miss.

  • Keep individual readings, including the range, rather than reporting only an average.
  • Record the instrument or gauge identification and its applicable verification status.
  • Apply the sampling locations and acceptance limits in the agreed plan. If a location is outside the limit, identify the affected screen and disposition before release.

Slot inspection confirms geometry against the specification. It does not by itself prove the correct sand-retention design. The well screen slot-size guide explains why formation and gravel-pack information belong in a separate design review.

Separate overall dimensions, active length and connections

Check the dimensions shown on the drawing: outside diameter, any required internal clearance, overall length, active filtering length, straightness and end geometry. Record the units consistently. A screen assembly’s total length includes more than its water-entry section.

Where specified, compare support-rod number and arrangement, wire profile and connection dimensions with the approved configuration. For threaded ends, use the applicable inspection method and specified gauges. For welded connections, check the joint preparation and interface dimensions required by the drawing. A connection that looks similar is not evidence of compatibility.

The OFD water well product range includes screens, casing, tail pipes and accessories. Review the interfaces between these components as an assembly, not only each item in isolation.

Trace material evidence to the supplied components

Review material records against the specified grade and link the relevant heat or batch identifiers to the supplied items. Where different materials are specified for wire, support rods or end fittings, review those components separately. An unlinked certificate is not enough to demonstrate which components it represents.

Surface appearance cannot distinguish 304 from 316 or establish chemical composition. Where material identification testing is required, record the method, locations and results, together with the method’s limitations. Do not assume that one identification method establishes every grade suffix or heat-treatment condition. See the 304 and 316 well screen material guide for the distinction between a grade description and supporting evidence.

Review welds, surface condition and the scope of tests

Inspect the accessible wire-to-support joints and end welds using the specified visual criteria. Record visible damage, distorted openings, loose elements or other findings for review. Check the required surface treatment and cleanliness, including removal of visible residues and protection against handling damage. A photograph of a bright surface does not establish weld strength or corrosion resistance.

Treat dimensional inspection, raw-material testing, welded-sample testing and collapse testing as different forms of evidence. If a test is specified, its report should identify the specimen or product, configuration, method, loading conditions, result and acceptance criterion. Confirm whether the report is a type test, a batch sample or a test of the delivered item; these scopes are not interchangeable.

OFD’s quality assurance page presents its raw-material, post-weld, collapse and process inspection activities. The applicable checks and release evidence remain those agreed for the particular product. No universal pressure rating or shipment result is inferred from the photographs.

Close findings and reconcile packing with the records

Before release, reconcile item identifiers, quantities and lengths with the packing list. Check end protection, separation and restraint during transport, and keep identification readable. Select packaging that protects the supplied configuration rather than assuming one packing method suits every length and connection.

  • Approved drawing and revision match the finished configuration.
  • Dimensional and slot records identify the inspected items and results.
  • Material and test records have the required traceability.
  • Any nonconformities have a documented disposition and required re-inspection.
  • Product markings, quantity, packing list and release documents agree.

Keep this evidence distinct from hydraulic claims. Open area and entrance velocity address water-entry geometry; they do not replace mechanical acceptance or a completed-well performance test.

Three questions to resolve before release

Does a nominal slot size prove that every opening complies? No. Compliance depends on the recorded measurements, the agreed inspection coverage and the specified limits.

Does one collapse-test photograph establish the rating of every supplied screen? No. The relevant evidence is the report and its documented applicability to the supplied configuration.

What makes the final inspection record useful? Clear product identification, the requirement checked, the method, actual findings and the release decision. A list of ticked boxes without these links is difficult to audit.

Back to News